Tel:
China Cryogenic Globe Valve manufacturer
SiChuan Liangchuan Mechanical Equipment Co.,Ltd

SiChuan Liangchuan Mechanical Equipment Co.,Ltd

Home ProductsFall Lift Safety Valve

PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank

PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank

    • PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank
    • PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank
  • PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank

    Product Details:

    Place of Origin: CHINA
    Brand Name: CNLN
    Certification: CE/ISO
    Model Number: Safety valve

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 pcs
    Price: USD110 per pc
    Packaging Details: Inner package:plastic bag sealed package Outer package:carton package or wooden case package The lettering, nameplate, certificate for valves are available
    Delivery Time: 5-8 work days
    Payment Terms: T/T
    Supply Ability: 3000pcs per month
    Contact Now
    Detailed Product Description
    Product Name: Cryogenic Safety Valve Power: Manual
    Material: Stainless Steel Structure: Safety Valve
    Application: Industry Valve Color: Customer Request
    High Light:

    LN2 Tank Fall Lift Safety Valve

    ,

    PN4.0MPa Fall Lift Safety Valve

    ,

    DN15 Cryogenic Safety Valve

    PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank

    Fall Lift Safety Valve Description

    Product specifications
     

    Product type: Spring direct acting full open
     

    Nominal pressure: 2.5MPa,4.0MPa
     

    Applicable medium: LO2, LN2, LAr, LNG, LC2H4, etc.
     

    Applicable temperature: -196 ~ + 80 ℃
     

    Connection: Thread


    Material of main parts
     

    Body and seat: stainless steel
     

    Spring: stainless steel        

     

    Disc Seal: Reinforced Teflon

     

    Customer Notice


    1. If customers have special requirements for products, they must provide the following instructions in the order contract:
    a. Structure length
    b. Connection Type;
    c. Nominal diameter
    d. Product use medium and temperature and pressure range;
    e. Testing, inspection standards and other requirements.

    2. The factory can configure various driving devices according to customer specific requirements.

     

    3. If the determined valve type and model are provided by the customer, the customer should correctly explain the meaning and requirements of its model, and sign the contract on the condition that the supply and demand sides understand and agree.
     

    4. For futures and ordering customers, please call the letter to tell the valve model, specifications, quantity, delivery time and place in detail. And advance payment of 30% of the total contract amount, the supplier is ready for production.

     

     

    PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank 0

    Valve Type:safety valve

    Connection Type: screw/thread

    Nominal Diameter:DN15~25mm

    Nominal Pressure:PN4.0MPa

    Set Pressure:0.92MPa,1.76 MPa,2.42 MPa

    Material: Valve Body:CF8;
    Valve Disc:06Cr19Ni10;

    Valve Seat:05Cr19Ni10;

    Seal material:PTFE;

    Suitable Medium:O2,N2,Ar,LNG,LCO2,etc

    Suitable Temparature:(-80℃~+120℃)

    Design and Manufacture:Conform to GB/T24925-2010

    Testing:Conform to GB/T13927-2008

    Valve Lifetime:Specified according to usage frequency

    and installation location

    Lead Time:Customized valves are usually 30~45 days; Stock valves are usually within 5 days.

     

     

    Notes Of Fall Lift Safety Valve

     

     

    1 . It should ensure that the pipe is blown clean before installation.

     

    2 . When installing, make sure that the flow direction indicated by the arrow on the valve body should be consistent with the flow direction of the fluid.

     

    3 . This valve has been degreased. Store and keep clean when installing.

     

    4 . After the pipeline construction is completed, all the valves on the pipeline should be opened, and the residue in the pipeline should be thoroughly and thoroughly kept to ensure that the pipeline system is clean and free of debris.

     

    5 . The installation system diagram with the oil-free requirements should be degreased.

     

    6 . Slowly open and close during use.

     

    7 . If the precision parts such as the valve disc, valve seat and valve stem are worn or damaged, it must be repaired and replaced in time.

     

    8 . For parts such as gaskets and sealing materials, replace them with new ones each time.

    Fall Lift Safety Valve Display

    PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank 1

     

     

    Fall Lift Safety Valve Specification

     

    Product Code

    Size

    H

    H1

    L

    M1

    M2

    D0

    D1

    D2

    C158DJ15

    179

    62

    47

    M45×2

    M36×2

    36

    15

    32

    C158DJ25

    159

    51

    46

    M30×1.5

    M30×1.5

    22

    12

    26

    PN4.0MPa DN15 Fall Lift Safety Valve For LN2 Tank 2

    FAQ

     

    Q. Are there any special requirements for OEM purchases?
    A. Yes. Liangchuan requires proof of trademark registration in order to print or emboss your trademark onto the product or packaging.

    Q. Do Liangchuan products come with a warranty ?
    A. Yes. That's why we offer 3-year product life guarantee, and a generous1 year warranty on all purchases that begins with the bill of loading.

    Q. How can I get some samples?

    A. Usually we don’t offer free sample and express fee are required, the sample cost can be deducted from your first large order.

    Q. What's the MOQ of your products?

    A. Our MOQ is one (1) piece/set.

    Q. Are you a manufacturer with your own factory?

    A. Yes, we are the manufacturer for more than 8 years

    Common Sense Of Fall Lift Safety Valve

    In recent years, ultra-low temperature valves have become more and more widely used, and they are one of the indispensable important equipment in petrochemical, air separation, natural gas and other industries. The working medium is not only low in temperature, but most of them are toxic, or flammable and explosive. , And strong permeability, so it determines many special requirements for valve materials and design. It is not only required to work normally at the set temperature, but also to ensure the working performance at room temperature.

    Compared with normal temperature valves, cryogenic valves have higher packing parts and use extended stems. Its purpose is to reduce the heat introduced into the device from the outside; to ensure that the temperature of the stuffing box is above 0°C, so that the packing can work normally; to prevent the valve stem and valve cover in the stuffing box from being too cold due to the part of the stuffing box The upper parts are frosted or frozen.

    Contact Details
    SiChuan Liangchuan Mechanical Equipment Co.,Ltd

    Contact Person: Bella

    Tel: +8613541399254

    Send your inquiry directly to us
    SiChuan Liangchuan Mechanical Equipment Co.,Ltd
    No.789,Baiyun Road,East Industrial Park,Xindu District,Chengdu City,Sichuan Province P.C. 610500
    Tel:86-28-83900998
    Mobile Site Privacy Policy China Good Quality Cryogenic Globe Valve Supplier. © 2020 - 2021 cryogeniccontrolvalve.com. All Rights Reserved.